CVE-2023-50222
Inductive Automation Ignition ResponseParser Notification Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.
The specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22067.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.15%
- Percentil entre todas las CVEs puntuadas: 66
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-502
- CWE-502
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-50222",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-50222",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-03T21:03:47.740884Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Inductive Automation",
"product": "Ignition",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"vendor": "inductiveautomation",
"product": "ignition",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-05-03T03:16:10.433",
"references": [
{
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b",
"tags": [
"Vendor Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-017/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-017/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-502"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-502"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ResponseParser Notification Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.\n\nThe specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22067."
},
{
"lang": "es",
"value": "Respuesta de encendido de automatización inductiva Notificación de Parser Deserialización de datos no confiables Vulnerabilidad de ejecución remota de código. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de Inductive Automation Ignition. Se requiere la interacción del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe conectarse a un servidor malicioso. La falla específica existe dentro del método ResponseParser. El problema se debe a la falta de una validación adecuada de los datos proporcionados por el usuario, lo que puede provocar la deserialización de datos que no son de confianza. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del usuario actual. Era ZDI-CAN-22067."
}
],
"lastModified": "2026-06-17T06:39:19.820",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D7B3DA7F-797B-4ADC-9F8F-3A0C4B18434F",
"versionEndExcluding": "8.1.35",
"versionStartIncluding": "8.1.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}