CVE-2023-50207
D-Link G416 flupl filename Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link G416 routers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the HTTP service listening on TCP port 80. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21300.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.92%
- Percentil entre todas las CVEs puntuadas: 59
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-50207",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-50207",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-06T14:09:15.313609Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "D-Link",
"product": "G416",
"versions": [
{
"status": "affected",
"version": "1.08b02"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:dlink:g416_firmware:1.08b02:*:*:*:*:*:*:*"
],
"vendor": "dlink",
"product": "g416_firmware",
"versions": [
{
"status": "affected",
"version": "1.08b02"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-05-03T03:16:06.860",
"references": [
{
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10367",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1823/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10367",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1823/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link G416 flupl filename Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link G416 routers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HTTP service listening on TCP port 80. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21300."
},
{
"lang": "es",
"value": "Vulnerabilidad de ejecución remota de código de inyección de comando de nombre de archivo flupl de D-Link G416. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de enrutadores D-Link G416. No se requiere autenticación para aprovechar esta vulnerabilidad. La falla específica existe dentro del servicio HTTP que escucha en el puerto TCP 80. El problema se debe a la falta de validación adecuada de una cadena proporcionada por el usuario antes de usarla para ejecutar una llamada al sistema. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto de la raíz. Era ZDI-CAN-21300."
}
],
"lastModified": "2026-06-17T06:39:17.920",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:g416_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9E44FE7B-CCEF-4118-9A02-810AFD0A22AE",
"versionEndExcluding": "1.09b01"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:g416:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E6E65179-A6A8-4A3A-8422-7171AF05B0CD"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}