CVE-2023-4816
Estado: ModificadaAlta (8.8)—
A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.61%
- Percentil entre todas las CVEs puntuadas: 48
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
- CWE-287
Referencias
- https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf
- https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-4816",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-4816",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-09-25T16:17:59.131708Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:L",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 4.7,
"exploitabilityScore": 1.7
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cybersecurity@hitachienergy.com",
"affectedData": [
{
"vendor": "Hitachi Energy",
"product": "Asset Suite 9",
"versions": [
{
"status": "affected",
"version": "9.6.3.11.0",
"versionType": "custom",
"lessThanOrEqual": "9.6.3.11.1"
},
{
"status": "affected",
"version": "9.6.4"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-09-11T08:15:07.917",
"references": [
{
"url": "https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@hitachienergy.com"
},
{
"url": "https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en la autenticación de Etiquetado de Equipos, cuando se configura con Inicio de Sesión Único con validación de contraseña en T214. Esta vulnerabilidad puede ser explotada por un usuario autenticado que realiza una acción de titular de Etiquetado de Equipo (Aceptar, Liberar y Borrar) para otro usuario e ingresa una contraseña arbitraria en el cuadro de diálogo de confirmación de la acción del titular. A pesar de ingresar una contraseña arbitraria en el cuadro de confirmación, el sistema ejecutará la acción del titular seleccionado."
}
],
"lastModified": "2026-06-17T06:38:40.123",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachienergy:asset_suite:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FAC84DA0-C8A5-433E-A812-7E182295CD06",
"versionEndIncluding": "9.6.3.11.1"
},
{
"criteria": "cpe:2.3:a:hitachienergy:asset_suite:9.6.4:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6D04B485-9331-43B1-A8D9-4C245E20738A"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@hitachienergy.com"
}