« Volver al listado

CVE-2023-45844

Estado: ModificadaMedia (6.8)—

The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug).

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-45844",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-45844",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-10T20:05:44.966105Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "psirt@bosch.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 7.3,
          "attackVector": "PHYSICAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 0.7
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.8,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@bosch.com",
      "affectedData": [
        {
          "vendor": "Rexroth",
          "product": "ctrlX HMI Web Panel - WR21 (WR2107)",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "vendor": "Rexroth",
          "product": "ctrlX HMI Web Panel - WR21 (WR2110)",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "vendor": "Rexroth",
          "product": "ctrlX HMI Web Panel - WR21 (WR2115)",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2107\\/:*:*:*:*:*:*:*:*"
          ],
          "vendor": "rexroth",
          "product": "ctrlx_hmi_web_panel_wr21\\/wr2107\\/",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "*"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2110\\/:*:*:*:*:*:*:*:*"
          ],
          "vendor": "rexroth",
          "product": "ctrlx_hmi_web_panel_wr21\\/wr2110\\/",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "*"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2115\\/:*:*:*:*:*:*:*:*"
          ],
          "vendor": "rexroth",
          "product": "ctrlx_hmi_web_panel_wr21\\/wr2115\\/",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "*"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-10-25T18:17:35.347",
  "references": [
    {
      "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "psirt@bosch.com"
    },
    {
      "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@bosch.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad permite a un usuario con pocos privilegios que tiene acceso al dispositivo cuando está bloqueado en modo quiosco instalar una aplicación Android arbitraria y aprovecharla para tener acceso a configuraciones críticas del dispositivo, como la administración de energía del dispositivo o, eventualmente, la configuración segura del dispositivo (depuración ADB). ."
    }
  ],
  "lastModified": "2026-06-17T06:29:38.463",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7FFA1309-DBEE-46F1-B6FD-DAE896180411"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "87C129B8-F100-4D3A-97BC-BAD9A4129F9D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "326E80AA-C9B4-4BF1-AA2B-98A3802A72C9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4CA92486-EEBE-42FD-9755-006B7F2DF361"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "167C9BC4-FCC5-4FAF-8F75-F967C77400A7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "psirt@bosch.com"
}