CVE-2023-45321
The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.12%
- Percentil entre todas las CVEs puntuadas: 2
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-319
- CWE-319
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-45321",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-45321",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-09-11T16:00:25.907168Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.5,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@bosch.com",
"affectedData": [
{
"vendor": "Bosch Rexroth AG",
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"vendor": "Bosch Rexroth AG",
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"vendor": "Bosch Rexroth AG",
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"vendor": "boschrexroth",
"product": "ctrlx_hmi_web_panel_wr2107",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "RC7(Build date 20231107)",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-10-25T18:17:33.183",
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "psirt@bosch.com"
},
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol."
},
{
"lang": "es",
"value": "La aplicación Cliente de Android, cuando se inscribe con el método de definición 1 (el usuario inserta manualmente la dirección IP del servidor), usa el protocolo HTTP para recuperar información confidencial (dirección IP y credenciales para conectarse a una entidad de intermediario MQTT remota) en lugar de HTTPS y esta característica. No es configurable por el usuario. Debido a la falta de cifrado de HTTP, este problema permite que un atacante ubicado en la misma red de subred del dispositivo HMI intercepte el nombre de usuario y la contraseña necesarios para autenticarse en el servidor MQTT responsable de implementar el protocolo de administración remota."
}
],
"lastModified": "2026-06-17T06:28:37.620",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7FFA1309-DBEE-46F1-B6FD-DAE896180411"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "87C129B8-F100-4D3A-97BC-BAD9A4129F9D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "326E80AA-C9B4-4BF1-AA2B-98A3802A72C9"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4CA92486-EEBE-42FD-9755-006B7F2DF361"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "167C9BC4-FCC5-4FAF-8F75-F967C77400A7"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@bosch.com"
}