« Volver al listado

CVE-2023-43488

Estado: ModificadaAlta (7.8)—

The vulnerability allows a low privileged (untrusted) application to modify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-43488",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-43488",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-11T13:32:31.772490Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "psirt@bosch.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 7.9,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 5.3,
        "exploitabilityScore": 2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@bosch.com",
      "affectedData": [
        {
          "vendor": "Rexroth",
          "product": "ctrlX HMI Web Panel - WR21 (WR2107)",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "vendor": "Rexroth",
          "product": "ctrlX HMI Web Panel - WR21 (WR2110)",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "vendor": "Rexroth",
          "product": "ctrlX HMI Web Panel - WR21 (WR2115)",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-10-25T18:17:31.800",
  "references": [
    {
      "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "psirt@bosch.com"
    },
    {
      "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@bosch.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-862"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-862"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The vulnerability allows a low privileged (untrusted) application to\r\nmodify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad permite que una aplicación con pocos privilegios (no confiable) modifique una propiedad crítica del sistema que debería negarse, para permitir que el protocolo ADB (Android Debug Bridge) quede expuesto en la red, explotándolo para obtener un shell privilegiado en el dispositivo. sin requerir el acceso físico a través de USB."
    }
  ],
  "lastModified": "2026-06-17T06:25:35.000",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7FFA1309-DBEE-46F1-B6FD-DAE896180411"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "87C129B8-F100-4D3A-97BC-BAD9A4129F9D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "326E80AA-C9B4-4BF1-AA2B-98A3802A72C9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4CA92486-EEBE-42FD-9755-006B7F2DF361"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "167C9BC4-FCC5-4FAF-8F75-F967C77400A7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "psirt@bosch.com"
}