CVE-2023-41255
Estado: ModificadaAlta (8.8)—
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication of the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.42%
- Percentil entre todas las CVEs puntuadas: 34
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-306
- CWE-306
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-41255",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-41255",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-09-10T19:04:46.249983Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@bosch.com",
"affectedData": [
{
"vendor": "Rexroth",
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"vendor": "Rexroth",
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"vendor": "Rexroth",
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"vendor": "boschrexroth",
"product": "ctrlx_hmi_web_panel_wr2107",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"vendor": "boschrexroth",
"product": "ctrlx_hmi_web_panel_wr2110",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"vendor": "boschrexroth",
"product": "ctrlx_hmi_web_panel_wr2115",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-10-25T18:17:30.737",
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "psirt@bosch.com"
},
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network."
},
{
"lang": "es",
"value": "La vulnerabilidad permite a un usuario sin privilegios con acceso a la subred del dispositivo TPC-110W obtener un shell raíz en el dispositivo abusando de la falta de autenticación del archivo binario 'su' instalado en el dispositivo al que se puede acceder a través del protocolo ADB (Android Debug Bridge) expuesto en la red."
}
],
"lastModified": "2026-06-17T06:21:22.520",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7FFA1309-DBEE-46F1-B6FD-DAE896180411"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "87C129B8-F100-4D3A-97BC-BAD9A4129F9D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "326E80AA-C9B4-4BF1-AA2B-98A3802A72C9"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4CA92486-EEBE-42FD-9755-006B7F2DF361"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "167C9BC4-FCC5-4FAF-8F75-F967C77400A7"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@bosch.com"
}