CVE-2023-39468
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.
The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.88%
- Percentil entre todas las CVEs puntuadas: 79
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-749
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-39468",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39468",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-08T17:19:46.064913Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Triangle MicroWorks",
"product": "SCADA Data Gateway",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"vendor": "trianglemicroworks",
"product": "scada_data_gateway",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-05-03T03:15:12.563",
"references": [
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"tags": [
"Release Notes"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"tags": [
"Release Notes"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-749"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Vulnerabilidad de ejecución remota de código de función peligrosa expuesta. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Se requiere autenticación para aprovechar esta vulnerabilidad. La falla específica existe en el manejo del parámetro DbasSectorFileToExecuteOnReset. El problema se debe a una función peligrosa expuesta. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto de SYSTEM. Era ZDI-CAN-20799."
}
],
"lastModified": "2026-06-17T06:12:23.807",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}