CVE-2023-38380

Estado: ModificadaAlta (8.7)—

A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl.

Leer descripción completaMostrar menos

SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.

An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (9)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-38380",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 8.7,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.4.29",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.4.29",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.4.29",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1243-7 LTE",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.4.29",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1243-8 IRC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.4.29",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1542SP-1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1543-1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.0.37",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1543SP-1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SINAMICS S210 (6SL5...)",
          "versions": [
            {
              "status": "affected",
              "version": "V6.1",
              "lessThan": "V6.1 HF2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS NET CP 1543-1",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.0.37",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-12-12T12:15:11.477",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-693975.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.\r\n\r\nAn attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en:\nSIMATIC CP 1242-7 V2 (incluidas las variantes SIPLUS) (todas las versiones), \nSIMATIC CP 1243-1 (incluidas las variantes SIPLUS) (todas las versiones), \nSIMATIC CP 1243-1 DNP3 (incluidas las variantes SIPLUS) ) (todas las versiones), \nSIMATIC CP 1243-1 IEC (incl. variantes SIPLUS) (todas las versiones), \nSIMATIC CP 1243-7 LTE (todas las versiones), \nSIMATIC CP 1243-8 IRC (todas las versiones), \nSIMATIC CP 1543-1 (Todas las versiones), \nSINAMICS S210 (6SL5...) (Todas las versiones &gt;= V6.1 &lt; V6.1 HF2), \nSIPLUS NET CP 1543-1 (Todas las versiones). \nLa implementación del servidor web de los productos afectados no libera correctamente la memoria asignada una vez utilizada. Un atacante con acceso a la red podría utilizar esta vulnerabilidad para provocar una condición de denegación de servicio en el servidor web del producto afectado."
    }
  ],
  "lastModified": "2026-06-17T06:10:02.430",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk7243-8rx30-0xe0_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BBBD0600-DB41-4DE8-97FC-2D180DA1406F"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk7243-8rx30-0xe0:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A50A52E7-D8FE-4071-99B3-3652B0892D07"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6gk7543-1ax00-0xe0_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EF7C15EC-3C83-434B-A313-9035302EEF87"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6gk7543-1ax00-0xe0:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E42E7B79-A3D2-4AAC-80E2-7E5C19A72CC5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1543-1ax00-2xe0_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9373F60E-03D0-4EB2-9774-6479A8F342C7"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1543-1ax00-2xe0:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F9063778-2B5F-4A32-83C8-6CEB9EE8F9C0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "66A2C7F2-F787-4770-8F56-E2AFF1AFD780"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "373B769D-0E60-4362-BAE1-90BA6E0B211C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1158D559-2A46-4BE4-B16E-C2789AD3C60E"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1C3E8B50-07E9-4697-B42D-86B9BE942553"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7FC29937-7A70-4A9F-89F8-8D17E285C225"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte:*:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "BAFC3319-F07C-4784-9873-3E1907FE3080"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BEBF14B3-65A0-41E9-B99C-D88548F307CD"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F151297C-3097-483F-98B5-0261BD547421"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1_hotfix8:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4CEAB952-BBF0-4585-8F12-F25A192FAA1B"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7F4D3F85-4CA5-438E-955E-C039F7DE91B1"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "59608DD3-87C3-4ED1-B0C2-AFD31A7A70A3"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix5:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EA3D3D7E-CB48-4B8D-8101-CB0DADEEC0B1"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix6:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6F8FC52F-3648-410B-8BCB-76129ABC0D4D"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:hotfix7:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "59BDCF31-2D94-4D7D-9EC8-60726B10DFC7"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D62C3EEA-000C-41CD-8264-4A4B6AE1BAD2"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EF00EE34-1A68-40F0-A9FC-FBBF268C6400"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix5:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C6BB896A-8C42-416E-AE03-D5A0E122BA79"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B18F1100-8157-4E99-AB22-BF51EB1663B3"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AA9B1D54-E3A0-4EFF-8EB2-A52B8E1F117F"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:6.1:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E509394F-9987-41D2-A866-68479FF39DCB"
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:6.1:hotfix1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2DEB162B-6579-4280-9BCC-403C1B351002"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}