« Volver al listado

CVE-2023-36952

Estado: ModificadaCrítica (9.8)—

Se descubrió que TOTOLINK CP300+ V5.2cu.7594_B20200910 contenía un desbordamiento de pila a través del parámetro pingIp en la función setDiagnosisCfg.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-36952",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-36952",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-16T18:51:00.899945Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:cp300\\+_firmware:5.2cu.7594_b20200910:*:*:*:*:*:*:*"
          ],
          "vendor": "totolink",
          "product": "cp300\\+_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "5.2cu.7594_b20200910"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-10-16T05:15:49.787",
  "references": [
    {
      "url": "https://github.com/Archerber/bug_submit/blob/main/TOTOLINK/CP300%2B_1.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/Archerber/bug_submit/blob/main/TOTOLINK/CP300%2B_1.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "TOTOLINK CP300+ V5.2cu.7594_B20200910 was discovered to contain a stack overflow via the pingIp parameter in the function setDiagnosisCfg."
    },
    {
      "lang": "es",
      "value": "Se descubrió que TOTOLINK CP300+ V5.2cu.7594_B20200910 contenía un desbordamiento de pila a través del parámetro pingIp en la función setDiagnosisCfg."
    }
  ],
  "lastModified": "2026-06-17T06:07:25.390",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:cp300\\+_firmware:5.2cu.7594_b20200910:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BD24E6CF-29AF-4828-8219-9EB5A54D62F2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:cp300\\+:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B07884CE-EB34-46ED-9361-F0228D3EB758"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}