CVE-2023-33379
Estado: ModificadaCrítica (9.8)—
Connected IO v2.1.0 and prior has a misconfiguration in their MQTT broker used for management and device communication, which allows devices to connect to the broker and issue commands to other device, impersonating Connected IO management platform and sending commands to all of Connected IO's devices.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.69%
- Percentil entre todas las CVEs puntuadas: 51
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-33379",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-33379",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-10-17T15:14:48.657156Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:connectedio:connected_io:*:*:*:*:*:*:*:*"
],
"vendor": "connectedio",
"product": "connected_io",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "v2.1.0"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-08-04T18:15:12.937",
"references": [
{
"url": "https://claroty.com/team82/disclosure-dashboard/cve-2023-33379",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.connectedio.com/products/routers",
"tags": [
"Product"
],
"source": "cve@mitre.org"
},
{
"url": "https://claroty.com/team82/disclosure-dashboard/cve-2023-33379",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.connectedio.com/products/routers",
"tags": [
"Product"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Connected IO v2.1.0 and prior has a misconfiguration in their MQTT broker used for management and device communication, which allows devices to connect to the broker and issue commands to other device, impersonating Connected IO management platform and sending commands to all of Connected IO's devices."
},
{
"lang": "es",
"value": "Connected IO v2.1.0 y anteriores tiene un error de configuración en su broker MQTT utilizado para la gestión y comunicación de dispositivos, que permite a los dispositivos conectarse al broker y emitir comandos a otro dispositivo, haciéndose pasar por la plataforma de gestión de Connected IO y enviando comandos a todos los dispositivos de Connected IO."
}
],
"lastModified": "2026-06-17T06:01:40.697",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:connectedio:er2000t-vz-cat1_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "99B02B1A-93F9-4617-B115-EE39272CFA13",
"versionEndIncluding": "2.1.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:connectedio:er2000t-vz-cat1:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B92433F3-2DF8-4398-BFFE-5BF2B0CE3B9D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}