CVE-2023-31174
Estado: ModificadaMedia (6.5)—
A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.
See Instruction Manual Appendix A and Appendix E dated 20230615 for more details.
This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-352
- CWE-352
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-31174",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-31174",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-09-30T15:44:33.294603Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security@selinc.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.4,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "security@selinc.com",
"affectedData": [
{
"vendor": "Schweitzer Engineering Laboratories",
"product": "SEL-5037 SEL Grid Configurator",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "4.5.0.20",
"versionType": "custom"
}
],
"platforms": [
"Windows"
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-08-31T16:15:09.827",
"references": [
{
"url": "https://selinc.com/support/security-notifications/external-reports/",
"tags": [
"Vendor Advisory"
],
"source": "security@selinc.com"
},
{
"url": "https://www.nozominetworks.com/blog/",
"tags": [
"Third Party Advisory"
],
"source": "security@selinc.com"
},
{
"url": "https://selinc.com/support/security-notifications/external-reports/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.nozominetworks.com/blog/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "security@selinc.com",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\nA Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
},
{
"lang": "es",
"value": "Una vulnerabilidad de falsificación de petición en sitios cruzados (CSRF) en el Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator podría permitir a un atacante incrustar instrucciones que podrían ser ejecutadas por un operador de dispositivo autorizado.\n\nConsulte el Apéndice A y el Apéndice E del Manual de Instrucciones con fecha 20230615 para más detalles.\n\nEste problema afecta a SEL-5037 SEL Grid Configurator: anterior a 4.5.0.20."
}
],
"lastModified": "2026-06-17T05:56:28.063",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8DE1284E-619F-49AC-AE96-0A4ECD76292B",
"versionEndExcluding": "4.5.0.20"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security@selinc.com"
}