CVE-2023-30796
Estado: ModificadaAlta (7.8)—
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-125
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-30796",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-30796",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-10-11T22:14:13.209203Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "JT Open",
"versions": [
{
"status": "affected",
"version": "All versions < V11.4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "JT Utilities",
"versions": [
{
"status": "affected",
"version": "All versions < V13.4"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-08-08T10:15:15.153",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT Open (Todas las versiones inferiores a V11.4), JT Utilities (Todas las versiones inferiores a V13.4). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada al analizar archivos JT especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."
}
],
"lastModified": "2026-06-17T05:55:42.730",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "125D935D-0DE5-4732-983B-8DC221479FB3",
"versionEndExcluding": "11.4"
},
{
"criteria": "cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C1B0B2A2-1A1A-4B0F-B957-2D5B6EBDB0FE",
"versionEndExcluding": "13.4"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}