« Volver al listado

CVE-2023-29241

Estado: ModificadaAlta (7.1)—

Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-29241",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-29241",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-26T19:59:44.994388Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "psirt@bosch.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.1,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@bosch.com",
      "affectedData": [
        {
          "vendor": "Bosch",
          "product": "BIS",
          "versions": [
            {
              "status": "affected",
              "version": "5.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-06-30T22:15:09.947",
  "references": [
    {
      "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "psirt@bosch.com"
    },
    {
      "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@bosch.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1112"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network"
    }
  ],
  "lastModified": "2026-06-17T05:49:39.180",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bosch:building_integration_system:5.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1B374A1E-F057-482A-B187-B704B259BADB"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@bosch.com"
}