CVE-2023-29158
Estado: ModificadaCrítica (9.1)—
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
- Puntuación base: 9.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.58%
- Percentil entre todas las CVEs puntuadas: 46
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-294
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-29158",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-29158",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-12-09T20:48:57.979110Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 0.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.1,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "SUBNET Solutions Inc.",
"product": "PowerSYSTEM Center",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2020 U10"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-06-19T21:15:42.033",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-294"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
}
],
"lastModified": "2026-06-17T05:49:30.420",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D5778648-23B8-4022-904D-E8B631E5FFD7",
"versionEndExcluding": "2020"
},
{
"criteria": "cpe:2.3:a:subnet:powersystem_center:2020:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7EDB93B1-836B-47CD-8D4A-4DFF281DEC91"
},
{
"criteria": "cpe:2.3:a:subnet:powersystem_center:2020:u10:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F5575977-3DFF-44B4-A0E1-4C3C9E92CD3E"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}