« Volver al listado

CVE-2023-29080

Estado: AplazadaAlta (8.5)—

Potential privilege escalation vulnerability in Revenera InstallShield versions 2022 R2 and 2021 R2 due to adding InstallScript custom action to a Basic MSI or InstallScript MSI project extracting few binaries to a predefined writable folder during installation time. The standard user account has write access to these files and folders, hence replacing them during installation time can lead to a DLL hijacking vulnerability.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:L, PR:L, sin UI:R → escalada local. DLL hijacking en carpeta escribible durante instalación permite ejecutar código con privilegios elevados.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-29080",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-29080",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-30T19:51:21.560312Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "PSIRT-CNA@flexerasoftware.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 8.5,
          "Automatable": "NOT_DEFINED",
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT-CNA@flexerasoftware.com",
      "affectedData": [
        {
          "vendor": "Revenera",
          "product": "InstallShield",
          "versions": [
            {
              "status": "affected",
              "changes": [
                {
                  "at": "InstallShield 2022 R2 Security Patch (28.0.0.763)",
                  "status": "unaffected"
                }
              ],
              "version": "2022 R2",
              "lessThan": "2022 R2 (28.0.0.763)",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "changes": [
                {
                  "at": "InstallShield 2021 R2 Security Patch (27.0.0.126)",
                  "status": "unaffected"
                }
              ],
              "version": "2021 R2",
              "lessThan": "2021 R2 (27.0.0.126)",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-01-30T18:15:28.437",
  "references": [
    {
      "url": "https://community.revenera.com/s/article/cve-2023-29080-security-patch-for-the-possible-privileged-escalation-scenarios-identified-in-installshield-nbsp",
      "source": "PSIRT-CNA@flexerasoftware.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "PSIRT-CNA@flexerasoftware.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-552"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Potential privilege escalation vulnerability in Revenera InstallShield versions 2022 R2 and 2021 R2 due to adding InstallScript custom action to a Basic MSI or InstallScript MSI project extracting few binaries to a predefined writable folder during installation time. The standard user account has write access to these files and folders, hence replacing them during installation time can lead to a DLL hijacking vulnerability."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad potencial de escalada de privilegios en las versiones 2022 R2 y 2021 R2 de Revenera InstallShield debido a la adición de una acción personalizada InstallScript a un proyecto MSI básico o MSI InstallScript que extrae algunos archivos binarios a una carpeta escribible predefinida durante el tiempo de instalación. La cuenta de usuario estándar tiene acceso de escritura a estos archivos y carpetas, por lo que reemplazarlos durante el tiempo de instalación puede provocar una vulnerabilidad de secuestro de DLL."
    }
  ],
  "lastModified": "2026-06-17T05:49:19.150",
  "sourceIdentifier": "PSIRT-CNA@flexerasoftware.com"
}