CVE-2023-28824
Estado: ModificadaMedia (4.9)—
Server-side request forgery vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 4.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.64%
- Percentil entre todas las CVEs puntuadas: 49
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-918
- CWE-918
Referencias
- https://jvn.jp/en/vu/JVNVU93372935/
- https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf
- https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf
- https://jvn.jp/en/vu/JVNVU93372935/
- https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf
- https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-28824",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28824",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-01-09T19:29:12.150296Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.2
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "Contec Co., Ltd.",
"product": "CONPROSYS HMI System (CHS)",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
]
}
],
"published": "2023-06-01T02:15:09.673",
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU93372935/",
"tags": [
"Third Party Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf",
"tags": [
"Vendor Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf",
"tags": [
"Vendor Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93372935/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-918"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-918"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Server-side request forgery vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database."
}
],
"lastModified": "2026-06-17T05:48:50.840",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "vultures@jpcert.or.jp"
}