« Volver al listado

CVE-2023-2876

Estado: ModificadaMedia (6.1)—

Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-2876",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-2876",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-03T01:58:48.969845Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@ch.abb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 3.1,
          "attackVector": "NETWORK",
          "baseSeverity": "LOW",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 1.6
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@ch.abb.com",
      "affectedData": [
        {
          "vendor": "ABB",
          "modules": [
            "firmware"
          ],
          "product": "REX640 PCL1",
          "versions": [
            {
              "status": "affected",
              "version": "1.0;0",
              "lessThan": "1.0.8",
              "versionType": "firmware update"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "ABB",
          "modules": [
            "Firmware"
          ],
          "product": "REX640 PCL2",
          "versions": [
            {
              "status": "affected",
              "version": "1.0;0",
              "lessThan": "1.1.4",
              "versionType": "firwmare update"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "ABB",
          "modules": [
            "firmware"
          ],
          "product": "REX640 PCL3",
          "versions": [
            {
              "status": "affected",
              "version": "1.0;0",
              "lessThan": "1.2.1",
              "versionType": "firwmare update"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-06-13T04:15:10.307",
  "references": [
    {
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001423&LanguageCode=en&DocumentPartId=&Action=Launch",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@ch.abb.com"
    },
    {
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001423&LanguageCode=en&DocumentPartId=&Action=Launch",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@ch.abb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1004"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.\n\n"
    }
  ],
  "lastModified": "2026-06-17T05:53:40.950",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:abb:rex640_pcl1_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EFB84892-676D-47BB-B099-5C74320B3E50",
              "versionEndExcluding": "1.0.8",
              "versionStartIncluding": "1.0.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:abb:rex640_pcl1:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9256FAAB-77CF-482C-B736-FC99885C89D7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:abb:rex640_pcl2_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "93001E90-E6B1-49BC-AA4E-CF3ED24A672E",
              "versionEndExcluding": "1.1.4",
              "versionStartIncluding": "1.0.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:abb:rex640_pcl2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "AE78102B-C672-4969-8B82-FE5ACE2FFC71"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:abb:rex640_pcl3_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E7A03D47-0F40-4C65-93AD-911687E3C4BB",
              "versionEndExcluding": "1.2.1",
              "versionStartIncluding": "1.0.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:abb:rex640_pcl3:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "90916E18-27EF-46C7-979B-19D53F901CC7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@ch.abb.com"
}