CVE-2023-28389
Estado: AplazadaMedia (6.7)—
Incorrect default permissions in some Intel(R) CSME installer software before version 2328.5.5.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 6.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.14%
- Percentil entre todas las CVEs puntuadas: 3
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-276
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-28389",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28389",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-03-14T18:27:01.638187Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "secure@intel.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.7,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.8
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Intel(R) CSME installer software",
"versions": [
{
"status": "affected",
"version": "before version 2328.5.5.0"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:intel:converged_security_and_manageability_engine:-:*:*:*:*:*:*:*"
],
"vendor": "intel",
"product": "converged_security_and_manageability_engine",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2328.5.5.0",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-03-14T17:15:50.333",
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00923.html",
"source": "secure@intel.com"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240912-0004/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00923.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "secure@intel.com",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect default permissions in some Intel(R) CSME installer software before version 2328.5.5.0 may allow an authenticated user to potentially enable escalation of privilege via local access."
},
{
"lang": "es",
"value": "Los permisos predeterminados incorrectos en algunos programas de instalación de Intel(R) CSME anteriores a la versión 2328.5.5.0 pueden permitir que un usuario autenticado habilite potencialmente la escalada de privilegios a través del acceso local."
}
],
"lastModified": "2026-06-17T05:47:36.710",
"sourceIdentifier": "secure@intel.com"
}