A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4).

Leer descripción completaMostrar menos

When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (13)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-27465",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.6,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 0.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.6,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIMOTION C240",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION C240 PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D410-2 DP",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D410-2 DP/PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D425-2 DP",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D425-2 DP/PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D435-2 DP",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D435-2 DP/PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D445-2 DP/PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D445-2 DP/PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION D455-2 DP/PN",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4 < V5.5 SP1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION P320-4 E",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMOTION P320-4 S",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V5.4"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-06-13T09:15:16.557",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-213"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device."
    }
  ],
  "lastModified": "2026-06-17T05:45:16.300",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d425-2_dp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0A65B54E-FE29-4352-8BA4-60C2F23F87F8",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d425-2_dp_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B6979F0F-FA12-422F-938D-0C84D39F69E9"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d425-2_dp:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CFD83F3F-CF11-44D9-8F9C-0B8D33BC3481"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d425-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "50C77E0A-9C5D-43EA-9157-C94CF4ACBE98",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d425-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "35BA3146-E138-48C5-BAFB-36FF795C8591"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d425-2_dp\\/pn:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1A007F9C-B6E3-4606-A7C2-B78E5F51C9BF"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d435-2_dp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "848DE61E-A4F9-4368-82AB-EA6FCD369EDB",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d435-2_dp_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EC2302CA-AD84-4FE8-98EA-7764A5B8978B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d435-2_dp:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "80932D46-6182-4B9D-9A66-BC381052DBF8"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d435-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FE2ACB98-373C-471C-B5A7-8D1BE59BBDA7",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d435-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AB781258-8A47-4388-A115-68ACF6CFD420"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d435-2_dp\\/pn:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3371CB24-AB41-44C7-93B7-78E2BD171D42"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d445-2_dp\\/pn_\\(0aa1\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B9B8C9F9-9474-4153-8CCA-60308E13543D",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d445-2_dp\\/pn_\\(0aa1\\)_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "117C8E63-C09D-412C-9B68-F2C72A8CCEDD"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d445-2_dp\\/pn_\\(0aa1\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DC9044F0-7E54-4C66-8613-A440B71D9D0D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d445-2_dp\\/pn_\\(0aa0\\)_firmware:5.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6B9D8FBD-E8E7-43E1-922F-973851E0D160"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d445-2_dp\\/pn_\\(0aa0\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "05D488BB-E0B5-46DF-B303-98524A39EEC2"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d455-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9CB06BE4-AA5C-4367-B34F-BB3FC17B9470",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d455-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "995B8740-C501-4448-9D22-4D115FAAE543"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d455-2_dp\\/pn:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "53FBAAA1-4012-463D-864B-C7BEAE15093E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_p320-4_e_firmware:5.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2C90B0F9-BBC8-417E-98FD-30BC069E769D"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_p320-4_e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "80DFB571-E3FA-44AA-B81C-AC7E13FFCB01"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_p320-4_s_firmware:5.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D49AFE41-D93E-4488-A5CB-AC48BB5921D6"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_p320-4_s:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4849FE93-67D0-496F-B47D-5035FF902540"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d410-2_dp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "91C51B40-4344-4796-AF7B-9F85D255A113",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d410-2_dp_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E2E25B36-BB4D-40B6-91A2-FC344E063B45"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d410-2_dp:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D2899391-D29A-4C95-A795-1B7EADCDF799"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d410-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "52950381-7B46-46F7-9B44-0313EA47EA87",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_d410-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BFA771D3-A08F-4690-853D-F07B47EC83AE"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_d410-2_dp\\/pn:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C6C5013B-BE8F-4635-9F7E-006EE737A4A0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_c240_pn_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "625A4A2B-37BB-4534-B1DD-3B18862F97BC",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_c240_pn_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2BE0D94D-FFF4-4913-9376-A3389579CC70"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_c240_pn:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2355A13D-6E84-4F35-8BE6-223C086E3719"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_c240_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "94035BD3-584A-4F93-A9AB-75A32F1628E2",
              "versionEndExcluding": "5.5",
              "versionStartIncluding": "5.4"
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_c240_firmware:5.5:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6E8FF00E-5125-4CD8-BD83-9F595ABA3B11"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion_c240:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "48B461ED-4B04-4EC2-B88E-F50D53509B1D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}