CVE-2023-25931
Estado: ModificadaMedia (6.8)—
Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an individual would need physical access to the Smart Programmer.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.27%
- Percentil entre todas las CVEs puntuadas: 17
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-620
- CWE-287
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-25931",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-25931",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-07T21:34:21.835531Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security@medtronic.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.4,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 5.5,
"exploitabilityScore": 0.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "security@medtronic.com",
"affectedData": [
{
"vendor": "Medtronic",
"product": "InsterStim Applications",
"versions": [
{
"status": "affected",
"version": "Micro Clinician ",
"lessThan": "A51200",
"versionType": "custom"
},
{
"status": "affected",
"version": "InterStim X Clinician",
"lessThan": "A51300",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-03-01T19:15:26.047",
"references": [
{
"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/pelvic-health-interstim-micro.html",
"tags": [
"Vendor Advisory"
],
"source": "security@medtronic.com"
},
{
"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/pelvic-health-interstim-micro.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "security@medtronic.com",
"description": [
{
"lang": "en",
"value": "CWE-620"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an individual would need physical access to the Smart Programmer. \n\n"
}
],
"lastModified": "2026-06-17T05:42:16.960",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:medtronic:interstim_x_clinician:a51300:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "81EEC6A7-21C5-46B5-83BD-C3BF94A6D41B"
},
{
"criteria": "cpe:2.3:a:medtronic:micro_clinician:a51200:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8BDDEB06-CB9C-4CD4-B0E1-59B870AAC7C1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security@medtronic.com"
}