« Volver al listado

CVE-2023-25911

Estado: AnalizadaAlta (8.8)—

The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-25911",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-25911",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-06T17:46:43.581155Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "csirt@divd.nl",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.9,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.1
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "csirt@divd.nl",
      "affectedData": [
        {
          "vendor": "Danfoss",
          "product": "AK-EM100",
          "versions": [
            {
              "status": "affected",
              "version": "< 2.2.0.12"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-06-11T14:15:09.923",
  "references": [
    {
      "url": "https://csirt.divd.nl/CVE-2023-25911/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "csirt@divd.nl"
    },
    {
      "url": "https://csirt.divd.nl/DIVD-2023-00021/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "csirt@divd.nl"
    },
    {
      "url": "https://csirt.divd.nl/DIVD-2023-00021",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://divd.nl/cves/CVE-2023-25911",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "csirt@divd.nl",
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters."
    }
  ],
  "lastModified": "2026-06-17T05:42:15.013",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:danfoss:ak-em100_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A0CC9DEC-BECF-45D3-ACAD-4762157DF3CB",
              "versionEndExcluding": "2.2.0.12"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:danfoss:ak-em100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "64202CC2-B89A-488C-A864-F4BBD2549ABE"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "csirt@divd.nl"
}