CVE-2023-2570
Estado: ModificadaAlta (7.8)—
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.16%
- Percentil entre todas las CVEs puntuadas: 5
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-129
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-2570",
"cveTags": [],
"metrics": {
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Foxboro DCS Control Core Services",
"versions": [
{
"status": "affected",
"version": "All versions prior to patch HF9857795"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-06-14T08:15:09.187",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-04.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-04.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-129"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nA CWE-129: Improper Validation of Array Index vulnerability exists that could cause local\ndenial-of-service, and potentially kernel execution when a malicious actor with local user access\ncrafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver.\n\n\n\n"
}
],
"lastModified": "2026-06-17T05:52:52.073",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_foxboro_dcs_control_core_services:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EBC5697C-C87E-4345-9A92-7CD48BB67683"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}