« Volver al listado

CVE-2023-25104

Estado: ModificadaAlta (7.2)—

Multiple buffer overflow vulnerabilities exist in the vtysh_ubus binary of Milesight UR32L v32.3.0.5 due to the use of an unsafe sprintf pattern. A specially crafted HTTP request can lead to arbitrary code execution. An attacker with high privileges can send HTTP requests to trigger these vulnerabilities.This buffer overflow occurs in the set_ike_profile function with the username and the password variables.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-25104",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-25104",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-14T16:14:48.887632Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "talos-cna@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "talos-cna@cisco.com",
      "affectedData": [
        {
          "vendor": "Milesight",
          "product": "UR32L",
          "versions": [
            {
              "status": "affected",
              "version": "v32.3.0.5"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:h:milesight:ur32l:-:*:*:*:*:*:*:*"
          ],
          "vendor": "milesight",
          "product": "ur32l",
          "versions": [
            {
              "status": "affected",
              "version": "v32.3.0.5"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-07-06T15:15:14.127",
  "references": [
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1716",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1716",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1716",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "talos-cna@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple buffer overflow vulnerabilities exist in the vtysh_ubus binary of Milesight UR32L v32.3.0.5 due to the use of an unsafe sprintf pattern. A specially crafted HTTP request can lead to arbitrary code execution. An attacker with high privileges can send HTTP requests to trigger these vulnerabilities.This buffer overflow occurs in the set_ike_profile function with the username and the password variables."
    }
  ],
  "lastModified": "2026-06-17T05:40:41.370",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:milesight:ur32l_firmware:32.3.0.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CF5F2502-0C97-4AC3-BD0A-45065C64F99B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:milesight:ur32l:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "224B5936-7A7A-48E7-B0F3-754B74E4BF2D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com"
}