CVE-2023-24837
Estado: ModificadaAlta (8.8)—
HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.93%
- Percentil entre todas las CVEs puntuadas: 59
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-24837",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-24837",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-02-19T16:27:33.835814Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "twcert@cert.org.tw",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "twcert@cert.org.tw",
"affectedData": [
{
"vendor": "HGiga",
"product": "PowerStation",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "x64.6.2.165",
"versionType": "custom"
}
]
}
]
}
],
"published": "2023-03-27T04:15:09.830",
"references": [
{
"url": "https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html",
"tags": [
"Third Party Advisory"
],
"source": "twcert@cert.org.tw"
},
{
"url": "https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "twcert@cert.org.tw",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service."
}
],
"lastModified": "2026-06-17T05:39:58.453",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hgiga:powerstation_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C3553132-CE95-4A61-9188-22D479C3E8A5",
"versionEndExcluding": "x64.6.2.165"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hgiga:powerstation:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4335A03A-1D0E-4DC9-A71B-FA627DB38B2F"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "twcert@cert.org.tw"
}