« Volver al listado

CVE-2023-22322

Estado: ModificadaMedia (5.5)—

Improper restriction of XML external entity reference (XXE) vulnerability exists in OMRON CX-Motion Pro 1.4.6.013 and earlier. If a user opens a specially crafted project file created by an attacker, sensitive information in the file system where CX-Motion Pro is installed may be disclosed.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-22322",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-22322",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-27T20:16:36.548819Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "vultures@jpcert.or.jp",
      "affectedData": [
        {
          "vendor": "OMRON Corporation",
          "product": "CX-Motion Pro",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.6.013 and earlier"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-01-30T07:15:09.237",
  "references": [
    {
      "url": "https://jvn.jp/en/vu/JVNVU94200979/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://jvn.jp/en/vu/JVNVU94200979/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper restriction of XML external entity reference (XXE) vulnerability exists in OMRON CX-Motion Pro 1.4.6.013 and earlier. If a user opens a specially crafted project file created by an attacker, sensitive information in the file system where CX-Motion Pro is installed may be disclosed."
    },
    {
      "lang": "es",
      "value": "Existe una restricción inadecuada de la vulnerabilidad de referencia de entidad externa XML (XXE) en OMRON CX-Motion Pro 1.4.6.013 y versiones anteriores. Si un usuario abre un archivo de proyecto especialmente manipulado creado por un atacante, se puede revelar información confidencial en el sistema de archivos donde está instalado CX-Motion Pro."
    }
  ],
  "lastModified": "2026-06-17T05:35:02.633",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:omron:cx-motion_pro:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "37398382-4AB8-4A93-A243-D5E0DC74D302",
              "versionEndExcluding": "1.4.6.014"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp"
}