« Volver al listado

CVE-2023-21993

Estado: ModificadaMedia (6.5)—

Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms). The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-21993",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-21993",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-16T14:38:26.620211Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "secalert_us@oracle.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "secalert_us@oracle.com",
      "affectedData": [
        {
          "vendor": "Oracle Corporation",
          "product": "Clinical Remote Data Capture Option",
          "versions": [
            {
              "status": "affected",
              "version": "5.4.0.2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-04-18T20:15:18.123",
  "references": [
    {
      "url": "https://www.oracle.com/security-alerts/cpuapr2023.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "secalert_us@oracle.com"
    },
    {
      "url": "https://www.oracle.com/security-alerts/cpuapr2023.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms).   The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture.  Successful attacks of this vulnerability can result in  unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts).  CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N)."
    }
  ],
  "lastModified": "2026-06-17T05:34:30.350",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:clinical_remote_data_capture:5.4.0.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "73DA7077-6EE5-44E2-BE90-2E0E8E3CEC7E"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "secalert_us@oracle.com"
}