Estado: ModificadaMedia (5.3)—

The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-1751",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-1751",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-16T20:55:59.191042Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "ics-cert@hq.dhs.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Nexx",
          "product": "Smart Alarm NXAL-100",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "nxal100v-p1-9-1"
            }
          ]
        },
        {
          "vendor": "Nexx",
          "product": "Smart Plug NXPG-100W",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "nxpg100cv4-0-0"
            }
          ]
        },
        {
          "vendor": "Nexx",
          "product": "Garage Door Controller NXG-100B, NXG-200",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "nxg200v-p3-4-1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-04-04T17:15:07.227",
  "references": [
    {
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-094-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-094-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId."
    }
  ],
  "lastModified": "2026-06-17T05:28:40.787",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:getnexx:nxal-100_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "ECEB2E75-CBB4-4698-8362-E299B360D230",
              "versionEndIncluding": "nxal100v-p1-9-1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:getnexx:nxal-100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A105A0A9-453D-4FEC-A892-90DF700AF48F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:getnexx:nxg-100b_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CFED44C1-D08F-485F-9613-2FF354646544",
              "versionEndIncluding": "nxg100bv-p3-4-1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:getnexx:nxg-100b:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "19767CB6-01EC-4D9A-B879-622D97659C41"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:getnexx:nxpg-100w_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "705949CF-FA4F-4D31-A125-897E4738FD60",
              "versionEndIncluding": "nxpg100cv4-0-0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:getnexx:nxpg-100w:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "BABBFCE0-C690-4867-9416-5C9E453A6B1F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:getnexx:nxg-200_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5D3856AF-F315-4D54-A415-23D870E57FDC",
              "versionEndIncluding": "nxg200v-p3-4-1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:getnexx:nxg-200:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E23E0481-74FD-4F0C-926C-D303DF9F9E68"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}