« Volver al listado

CVE-2023-0850

Estado: ModificadaAlta (7.5)—

A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-0850",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:M/C:N/I:N/A:P",
          "authentication": "MULTIPLE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 2.7,
          "attackVector": "NETWORK",
          "baseSeverity": "LOW",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Netgear",
          "modules": [
            "Web Interface"
          ],
          "product": "WNDR3700v2",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.1.14"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-02-15T22:15:12.323",
  "references": [
    {
      "url": "https://vuldb.com/?ctiid.221153",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.221153",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?ctiid.221153",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?id.221153",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-404"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability."
    }
  ],
  "lastModified": "2026-06-17T05:26:27.113",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:1.0.1.14:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C070DBCF-B268-4CD5-B914-BBD115E219A9"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wndr3700:v2:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7C0FE2FB-A508-4429-86F4-FFE93C1DA055"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}