CVE-2023-0612
Estado: ModificadaAlta (7.5)—
A vulnerability, which was classified as critical, was found in TRENDnet TEW-811DRU 1.0.10.0. Affected is an unknown function of the file /wireless/basic.asp of the component httpd. The manipulation leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-219936.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.85%
- Percentil entre todas las CVEs puntuadas: 57
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-120
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-0612",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "TRENDnet",
"modules": [
"httpd"
],
"product": "TEW-811DRU",
"versions": [
{
"status": "affected",
"version": "1.0.10.0"
}
]
}
]
}
],
"published": "2023-02-01T14:15:09.227",
"references": [
{
"url": "https://vuldb.com/?ctiid.219936",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.219936",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.219936",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.219936",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in TRENDnet TEW-811DRU 1.0.10.0. Affected is an unknown function of the file /wireless/basic.asp of the component httpd. The manipulation leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-219936."
}
],
"lastModified": "2026-06-17T05:25:55.567",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:trendnet:tew-811dru_firmware:1.0.10.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "25BB401A-411B-423C-A878-04C8D7A0AD17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:trendnet:tew-811dru:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "525C167E-32FA-44C2-B6E2-BFE01F28592E"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}