« Volver al listado

CVE-2022-47036

Estado: AplazadaCrítica (9.8)—

Siklu TG Terragraph devices before approximately 2.1.1 have a hardcoded root password that has been revealed via a brute force attack on an MD5 hash. It can be used for "debug login" by an admin. NOTE: the vulnerability is not fixed by the 2.1.1 firmware; instead, it is fixed in newer hardware, which would typically be used with firmware 2.1.1 or later.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-47036",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-47036",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-27T16:14:29.668870Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:siklu:tg_terragraph:*:*:*:*:*:*:*:*"
          ],
          "vendor": "siklu",
          "product": "tg_terragraph",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.1.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-03-18T03:15:05.957",
  "references": [
    {
      "url": "https://semaja2.net/2023/06/11/siklu-tg-auth-bypass.html",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://semaja2.net/2023/06/11/siklu-tg-auth-bypass.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Siklu TG Terragraph devices before approximately 2.1.1 have a hardcoded root password that has been revealed via a brute force attack on an MD5 hash. It can be used for \"debug login\" by an admin. NOTE: the vulnerability is not fixed by the 2.1.1 firmware; instead, it is fixed in newer hardware, which would typically be used with firmware 2.1.1 or later."
    },
    {
      "lang": "es",
      "value": "Los dispositivos Siklu TG Terragraph anteriores a aproximadamente 2.1.1 tienen una contraseña de root codificada que se ha revelado mediante un ataque de fuerza bruta en un hash MD5. Un administrador puede utilizarlo para \"iniciar sesión de depuración\". NOTA: la vulnerabilidad no se soluciona con el firmware 2.1.1; en cambio, se soluciona en hardware más nuevo, que normalmente se usaría con el firmware 2.1.1 o posterior."
    }
  ],
  "lastModified": "2026-06-17T05:12:55.280",
  "sourceIdentifier": "cve@mitre.org"
}