CVE-2022-46670
Estado: ModificadaMedia (6.1)—
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 6.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.56%
- Percentil entre todas las CVEs puntuadas: 45
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (5)
CWE
- CWE-79
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-46670",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-46670",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-17T14:35:20.399901Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.7,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "MicroLogix 1100 & 1400 Controllers",
"versions": [
{
"status": "affected",
"version": "All"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Rockwell Automation",
"product": "MicroLogix 1400-B/C",
"versions": [
{
"status": "affected",
"version": "21.007 and below"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Rockwell Automation",
"product": "MicroLogix 1400-A",
"versions": [
{
"status": "affected",
"version": "7.000 and below"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2022-12-16T21:15:09.040",
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679",
"tags": [
"Vendor Advisory"
],
"source": "PSIRT@rockwellautomation.com"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n"
},
{
"lang": "es",
"value": "Un investigador de seguridad del Instituto de Tecnología de Georgia informó a Rockwell Automation de una vulnerabilidad que indica que los controladores MicroLogix 1100 y 1400 contienen una vulnerabilidad que puede brindarle a un atacante la capacidad de realizar la ejecución remota de código. La vulnerabilidad es de Cross-Site Scripting almacenado, no autenticada en el servidor web integrado. El payload se transfiere al controlador a través de SNMP y se representa en la página de inicio del sitio web integrado."
}
],
"lastModified": "2026-06-17T05:12:10.090",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "11507EFF-5C53-4217-9257-21936118C032"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "196EA0BE-FDF3-46BE-B3DA-5F49208C5D80"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DCE86CDF-12CC-4B02-942D-BF9134218F2B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DA42C7F4-EEC1-44D2-BD46-237969FF6E1A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-b_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E6C4D215-CB09-4BEA-89A6-2BAACD461FBE",
"versionEndIncluding": "21.007"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3D01BD0A-CA96-4882-8523-EC4D522DA4AF"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD745E1D-10D9-4FD6-9F7C-63CB51F3C454",
"versionEndIncluding": "21.007"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DC9A2DE5-E745-4F1B-931C-E11814A7D23A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-a_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2E2B3E77-CF64-4D7F-A849-5462CABB576D",
"versionEndIncluding": "7.000"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-a:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "81AFED05-B927-4BF7-ABC5-5E3F7555593D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}