« Volver al listado

CVE-2022-43513

Estado: ModificadaAlta (7.5)—

A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected components allow to rename license files with user chosen input without authentication. This could allow an unauthenticated remote attacker to rename and move files as SYSTEM user.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-43513",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-43513",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-09T14:05:09.779623Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Automation License Manager V5",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Automation License Manager V6",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V6.0 SP9 Upd4"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "TeleControl Server Basic V3",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.1.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-01-10T12:15:23.207",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected components allow to rename license files with user chosen input without authentication.\r\nThis could allow an unauthenticated remote attacker to rename and move files as SYSTEM user."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Automation License Manager V5 (todas las versiones), Automation License Manager V6 (todas las versiones &lt; V6.0 SP9 Upd4). Los componentes afectados permiten cambiar el nombre de los archivos de licencia con la entrada elegida por el usuario sin autenticación. Esto podría permitir que un atacante remoto no autenticado cambie el nombre y mueva archivos como usuario de SYSTEM."
    }
  ],
  "lastModified": "2026-06-17T05:06:44.170",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.0.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "57DAB83B-D831-4DB8-A4BA-110B49EE2696"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B0233F2E-C041-40D5-AB8F-F6C379924615"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.1:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CDA04752-6735-4BBF-B5B2-801055CEB3F1"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8C899294-1A84-4462-A4FC-37AAC939A3E6"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.3:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DD772F21-BC75-4DBA-948B-ED73ED3594F4"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.3:sp3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7825B35F-204E-43A6-9CE3-087CEBB63F6E"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:5.3.4.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F1424C77-4F58-4392-9DF0-880FF03EF5E5"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:6.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F9947563-20B4-4FB5-88AE-54D47FA397DA"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:6.0.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A717A185-083A-49A1-B5E3-E6D678643916"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:6.0.8:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "206F9776-74CB-4CFA-A92E-63C739FA8771"
            },
            {
              "criteria": "cpe:2.3:a:siemens:automation_license_manager:6.0.9:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FA349550-EA76-4C27-B681-1846C977EE8A"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}