« Volver al listado

CVE-2022-43101

Estado: ModificadaCrítica (9.8)—

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-43101",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-43101",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-02T19:34:09.171724Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-11-03T14:15:25.923",
  "references": [
    {
      "url": "https://github.com/ppcrab/IOT_FIRMWARE/blob/main/Tenda/ac23/ac23.md#formsetdevicenameset_device_namesprintfv4-s1-a1",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/ppcrab/IOT_FIRMWARE/blob/main/Tenda/ac23/ac23.md#formsetdevicenameset_device_namesprintfv4-s1-a1",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
    },
    {
      "lang": "es",
      "value": "Se descubrió que Tenda AC23 V16.03.07.45_cn contenía un desbordamiento de pila a través del parámetro devName en la función formSetDeviceName."
    }
  ],
  "lastModified": "2026-06-17T05:05:54.687",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FC6E7859-D418-487C-A318-8514A6EABD8D"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9B730D9E-D9B0-480B-9941-7C48C56BBE94"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}