« Volver al listado

CVE-2022-41663

Estado: ModificadaAlta (7.8)—

A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-41663",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-41663",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-18T15:22:20.315951Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "JT2Go",
          "versions": [
            {
              "status": "affected",
              "version": "All versions <  V14.1.0.4"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V13.2",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V13.2.0.12"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V13.3",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V13.3.0.7"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V14.0",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V14.0.0.3"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V14.1",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V14.1.0.4"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2022-11-08T11:15:11.753",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in JT2Go (All versions <  V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V14.1.0.4), \nTeamcenter Visualization V13.2 (Todas las versiones &lt; V13.2.0.12), \nTeamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0. 7), \nTeamcenter Visualization V14.0 (todas las versiones &lt; V14.0.0.3), \nTeamcenter Visualization V14.1 (todas las versiones &lt; V14.1.0.4). \nLas aplicaciones afectadas contienen una vulnerabilidad de use-after-free que podría activarse al analizar archivos CGM especialmente manipulados. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual."
    }
  ],
  "lastModified": "2026-06-17T05:03:35.557",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FD5EAF75-B0F4-4792-9833-085B9D830FCE",
              "versionEndExcluding": "14.1.0.4"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FB99D790-4F55-48F2-902B-8739CAEC78EE",
              "versionEndExcluding": "13.3.0.7",
              "versionStartIncluding": "13.3.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0F811DB6-3650-4BCB-A538-AAECF63EA085",
              "versionEndExcluding": "14.0.0.3",
              "versionStartIncluding": "14.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "175648D0-81ED-4AC9-AF2D-4C9E93814C36",
              "versionEndExcluding": "14.1.0.4",
              "versionStartIncluding": "14.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}