« Volver al listado

CVE-2022-41142

Estado: ModificadaAlta (8.8)—

This vulnerability allows remote attackers to escalate privileges on affected installations of Centreon. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of requests to configure poller resources. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to escalate privileges to the level of an administrator. Was ZDI-CAN-18304.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-41142",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-41142",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-31T15:46:20.144242Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "zdi-disclosures@trendmicro.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Centreon",
          "product": "Centreon",
          "versions": [
            {
              "status": "affected",
              "version": "22.04.2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-01-26T18:59:53.877",
  "references": [
    {
      "url": "https://github.com/centreon/centreon/security/policy",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1326/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    },
    {
      "url": "https://github.com/centreon/centreon/security/policy",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1326/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "zdi-disclosures@trendmicro.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to escalate privileges on affected installations of Centreon. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of requests to configure poller resources. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to escalate privileges to the level of an administrator. Was ZDI-CAN-18304."
    },
    {
      "lang": "es",
      "value": "Esta vulnerabilidad permite a atacantes remotos escalar privilegios en las instalaciones afectadas de Centreon. Se requiere autenticación para aprovechar esta vulnerabilidad. La falla específica existe en el manejo de solicitudes para configurar los recursos del sondeador. El problema se debe a la falta de validación adecuada de una cadena proporcionada por el usuario antes de usarla para construir consultas SQL. Un atacante puede aprovechar esta vulnerabilidad para escalar privilegios al nivel de administrador. Era ZDI-CAN-18304."
    }
  ],
  "lastModified": "2026-06-17T05:02:40.623",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:centreon:centreon:22.04.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D4E656A3-6609-4CA9-BBCA-28261D225D29"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com"
}