« Volver al listado

CVE-2022-39065

Estado: ModificadaMedia (6.5)—

A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-39065",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-39065",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-15T13:44:59.292209Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@synopsys.com",
      "affectedData": [
        {
          "vendor": "Ikea",
          "product": "TRÅDFRI gateway system",
          "versions": [
            {
              "status": "affected",
              "version": "< 1.19.26"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-10-14T16:15:19.243",
  "references": [
    {
      "url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@synopsys.com"
    },
    {
      "url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@synopsys.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-241"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
    },
    {
      "lang": "es",
      "value": "Una única trama IEEE 802.15.4 (Zigbee) malformada hace que la pasarela TRÅDFRI no responda, de modo que la iluminación conectada no puede controlarse con la aplicación IKEA Home Smart y el mando a distancia TRÅDFRI. La trama Zigbee malformada es un mensaje de difusión no autenticado, lo que significa que todos los dispositivos vulnerables dentro del rango de radio están afectados. CVSS 3.1, Puntuación Base 6.5, Vector CVSS: 3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
    }
  ],
  "lastModified": "2026-06-17T04:57:31.900",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ikea:tradfri_gateway_e1526_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CCEFB34F-7A58-4FFC-A8A2-42A369D271E3",
              "versionEndExcluding": "1.19.26"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ikea:tradfri_gateway_e1526:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "FE61F613-9822-4B7D-BB22-15F6B0107DFB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "disclosure@synopsys.com"
}