« Volver al listado

CVE-2022-3884

Estado: ModificadaAlta (7.1)—

Incorrect Default Permissions vulnerability in Hitachi Ops Center Analyzer on Windows (Hitachi Ops Center Analyzer RAID Agent component) allows local users to read and write specific files.This issue affects Hitachi Ops Center Analyzer: from 10.9.0-00 before 10.9.0-01.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-3884",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-3884",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-07T18:14:22.527808Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "hirt@hitachi.co.jp",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 7.3,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4.7,
        "exploitabilityScore": 2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.1,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "hirt@hitachi.co.jp",
      "affectedData": [
        {
          "vendor": "Hitachi",
          "modules": [
            "Hitachi Ops Center Analyzer RAID Agent"
          ],
          "product": "Hitachi Ops Center Analyzer",
          "versions": [
            {
              "status": "affected",
              "changes": [
                {
                  "at": "10.9.0-01",
                  "status": "unaffected"
                }
              ],
              "version": "10.9.0-00",
              "lessThan": "10.9.0-01",
              "versionType": "custom"
            }
          ],
          "platforms": [
            "Windows"
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-02-28T03:15:09.243",
  "references": [
    {
      "url": "https://www.hitachi.com/products/it/software/security/info/vuls/hitachi-sec-2023-105/index.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "hirt@hitachi.co.jp"
    },
    {
      "url": "https://www.hitachi.com/products/it/software/security/info/vuls/hitachi-sec-2023-105/index.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "hirt@hitachi.co.jp",
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Incorrect Default Permissions vulnerability in Hitachi Ops Center Analyzer on Windows (Hitachi Ops Center Analyzer RAID Agent component) allows local users to read and write specific files.This issue affects Hitachi Ops Center Analyzer: from 10.9.0-00 before 10.9.0-01.\n\n"
    }
  ],
  "lastModified": "2026-06-17T05:00:30.267",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hitachi:ops_center_analyzer:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "374B68D0-84F5-451F-96D8-6386618FFF57",
              "versionEndExcluding": "10.9.1-00",
              "versionStartIncluding": "10.9.0-00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:x64:*",
              "vulnerable": false,
              "matchCriteriaId": "82132539-3C34-4B63-BE2A-F51077D8BC5A"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "hirt@hitachi.co.jp"
}