« Volver al listado

CVE-2022-37012

Estado: ModificadaAlta (7.5)—

This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-37012",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-37012",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-02-18T19:34:15.764429Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "zdi-disclosures@trendmicro.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Unified Automation",
          "product": "OPC UA C++ Demo Server",
          "versions": [
            {
              "status": "affected",
              "version": "1.7.6-537"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-03-29T19:15:12.827",
  "references": [
    {
      "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt",
      "tags": [
        "Release Notes"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    },
    {
      "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt",
      "tags": [
        "Release Notes"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "zdi-disclosures@trendmicro.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-911"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927."
    }
  ],
  "lastModified": "2026-06-17T04:54:27.880",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:unified-automation:opc_ua_c\\+\\+_demo_server:1.7.6.537:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "389A3E3E-164D-44D8-95DF-DD21308ACA35"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com"
}