« Volver al listado

CVE-2022-34456

Estado: ModificadaAlta (8.8)—

Dell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-34456",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-34456",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-02T16:24:27.350882Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell EMC",
          "product": "Metro node",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "7.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-01-18T06:15:11.577",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000204057/dsa-2022-267-dell-emc-metronode-vs5-security-update-for-multiple-third-party-component-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000204057/dsa-2022-267-dell-emc-metronode-vs5-security-update-for-multiple-third-party-component-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nDell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.\n\n\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "El nodo Dell EMC Metro, en las versiones anteriores a la 7.1, contiene una vulnerabilidad de inyección de código. Un atacante autenticado y sin privilegios podría explotar esta vulnerabilidad, lo que llevaría a la ejecución de comandos arbitrarios del sistema operativo en la aplicación."
    }
  ],
  "lastModified": "2026-06-17T04:50:23.387",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_metro_node:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D143E891-A916-4E13-A055-C54D02C38D50",
              "versionEndExcluding": "7.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}