CVE-2022-34100
Estado: ModificadaAlta (8.8)—
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.19%
- Percentil entre todas las CVEs puntuadas: 67
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-34100",
"cveTags": [],
"metrics": {
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2022-09-13T19:15:09.953",
"references": [
{
"url": "https://www.crestron.com/Security/Security_Advisories",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf",
"tags": [
"Release Notes",
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.crestron.com/Security/Security_Advisories",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf",
"tags": [
"Release Notes",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad en Crestron AirMedia Windows Application, versión 4.3.1.39, en la que un usuario poco privilegiado puede conseguir una solicitud de comando a nivel SYSTEM al preconfigurar una estructura de archivos antes de la instalación de un ejecutable de servicio confiable y cambiar los permisos en esa estructura de archivos durante una operación de reparación"
}
],
"lastModified": "2026-06-17T04:49:44.077",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:crestron:airmedia:4.3.1.39:*:*:*:*:windows:*:*",
"vulnerable": true,
"matchCriteriaId": "92342A07-1DFE-43D8-895E-D05C5EE63FEC"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}