CVE-2022-3120
Estado: ModificadaCrítica (9.8)—
A vulnerability classified as critical was found in SourceCodester Clinics Patient Management System. Affected by this vulnerability is an unknown functionality of the file index.php of the component Login. The manipulation of the argument user_name leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-207847.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.76%
- Percentil entre todas las CVEs puntuadas: 54
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-3120",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-3120",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-11T20:54:17.476138Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "SourceCodester",
"product": "Clinics Patient Management System",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2022-09-05T07:15:08.250",
"references": [
{
"url": "https://github.com/joinia/webray.com.cn/blob/main/Clinic%27s-Patient-Management-System/cpms.md",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.207847",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/joinia/webray.com.cn/blob/main/Clinic%27s-Patient-Management-System/cpms.md",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.207847",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in SourceCodester Clinics Patient Management System. Affected by this vulnerability is an unknown functionality of the file index.php of the component Login. The manipulation of the argument user_name leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-207847."
},
{
"lang": "es",
"value": "Se ha encontrado una vulnerabilidad clasificada como crítica en SourceCodester Clinics Patient Management System. Esta vulnerabilidad afecta a una funcionalidad desconocida del archivo index.php del componente Login. La manipulación del argumento user_name conlleva a una inyección sql. El ataque puede ser lanzado remotamente. La explotación ha sido divulgada al público y puede ser usada. El identificador asociado a esta vulnerabilidad es VDB-207847"
}
],
"lastModified": "2026-06-17T04:58:54.180",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:oretnom23:clinic\\'s_patient_management_system:1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7B79041F-F46A-46A6-927D-98ECD0A65838"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cna@vuldb.com"
}