Estado: ModificadaCrítica (9.1)—

Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-29830",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-29830",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-25T17:50:31.923830Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "affectedData": [
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "GX Works3",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.095Z"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "Motion Control Setting(GX Works3 related software)",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.065T"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2022-11-25T00:15:10.367",
  "references": [
    {
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "description": [
        {
          "lang": "en",
          "value": "CWE-321"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
    },
    {
      "lang": "es",
      "value": "El uso de una vulnerabilidad de clave criptográfica codificada en Mitsubishi Electric GX Works3 en las versiones 1.000A hasta 1.095Z y la configuración de control de movimiento (software relacionado con GX Works3) de 1.000A y posteriores permite a un atacante remoto no autenticado revelar o alterar información sensible. Como resultado, los atacantes no autenticados pueden obtener información sobre archivos de proyecto de forma ilegal."
    }
  ],
  "lastModified": "2026-06-17T04:40:47.300",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a"
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r"
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}