« Volver al listado

CVE-2022-29825

Estado: ModificadaAlta (7.5)—

Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-29825",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-29825",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-25T17:52:17.273503Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 5.6,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4,
        "exploitabilityScore": 1.1
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "affectedData": [
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "GX Works3",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.090U"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "GT Designer3 Version1 (GOT2000)",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.122C to 1.290C"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "MT Works2",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.100E to 1.200J"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2022-11-25T00:15:10.000",
  "references": [
    {
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
    },
    {
      "lang": "es",
      "value": "El uso de la vulnerabilidad de contraseña codificada en las versiones Mitsubishi Electric GX Works3 de 1.000A a 1.090U y GT Designer3 Versión1 (GOT2000) de 1.122C a 1.290C permite que un atacante no autenticado revele información sensible. Como resultado, los usuarios no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
    }
  ],
  "lastModified": "2026-06-17T04:40:46.717",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a"
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r"
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}