CVE-2022-26388
Estado: AplazadaMedia (6.4)—
A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph:
Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:
Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:
Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:
Versions 2.2.0 and prior.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
- Puntuación base: 6.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.27%
- Percentil entre todas las CVEs puntuadas: 17
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (9)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-259
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-26388",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-26388",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-02-07T18:50:50.198188Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.4,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.5,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "productsecurity@baxter.com",
"affectedData": [
{
"vendor": "Welch Allyn",
"product": "ELI 380 Resting Electrocardiograph",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2.6.0"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Welch Allyn",
"product": "ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2.3.1"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Welch Allyn",
"product": "ELI 250c/BUR 250c Resting Electrocardiograph",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2.1.2"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Welch Allyn",
"product": "ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2.2.0"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-02-07T17:15:21.960",
"references": [
{
"url": "https://hillrom.com/en/responsible-disclosures/",
"source": "productsecurity@baxter.com"
},
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01",
"source": "productsecurity@baxter.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productsecurity@baxter.com",
"description": [
{
"lang": "en",
"value": "CWE-259"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: \n\nVersions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:\n\nVersions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior."
},
{
"lang": "es",
"value": "Una vulnerabilidad en el uso de contraseñas codificadas de forma rígida puede permitir el abuso de la autenticación. Este problema afecta al electrocardiógrafo en reposo ELI 380: versiones 2.6.0 y anteriores; al electrocardiógrafo en reposo ELI 280/BUR280/MLBUR 280: versiones 2.3.1 y anteriores; al electrocardiógrafo en reposo ELI 250c/BUR 250c: versiones 2.1.2 y anteriores; al electrocardiógrafo en reposo ELI 150c/BUR 150c/MLBUR 150c: versiones 2.2.0 y anteriores."
}
],
"lastModified": "2026-06-17T04:35:08.587",
"sourceIdentifier": "productsecurity@baxter.com"
}