Estado: ModificadaAlta (7.2)—

A vulnerability has been identified in SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-24281",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-24281",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-18T15:23:48.505857Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Secondary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC NMS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V1.0.3"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SINEMA Server V14",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2022-03-08T12:15:11.403",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-250085.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-250085.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones anteriores a la versión V1.0.3). Un atacante autentificado con privilegios podría ejecutar comandos arbitrarios en la base de datos local enviando peticiones especialmente diseñadas al servidor web de la aplicación afectada"
    }
  ],
  "lastModified": "2026-06-17T04:31:32.497",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0D14E8FC-464B-414D-AE56-C20FF46E25FB",
              "versionEndExcluding": "1.0.3"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}