CVE-2022-2347
Estado: ModificadaAlta (7.1)—
There exists an unchecked length field in UBoot. The U-Boot DFU implementation does not bound the length field in USB DFU download setup packets, and it does not verify that the transfer direction corresponds to the specified command. Consequently, if a physical attacker crafts a USB DFU download setup packet with a `wLength` greater than 4096 bytes, they can write beyond the heap-allocated request buffer.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.58%
- Percentil entre todas las CVEs puntuadas: 46
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-122
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-2347",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-2347",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-21T13:39:55.300279Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve-coordination@google.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.7,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.1,
"attackVector": "PHYSICAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 0.5
}
]
},
"affected": [
{
"source": "cve-coordination@google.com",
"affectedData": [
{
"vendor": "Uboot",
"product": "Uboot",
"versions": [
{
"status": "affected",
"version": "unspecified",
"versionType": "custom",
"lessThanOrEqual": "2022.07"
}
]
}
]
},
{
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"affectedData": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX MX5000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX MX5000RE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1400",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1500",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1501",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1510",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1511",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1512",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1524",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1536",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX5000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2022-09-23T13:15:10.133",
"references": [
{
"url": "https://seclists.org/oss-sec/2022/q3/41",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"source": "cve-coordination@google.com"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2025/05/msg00001.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://seclists.org/oss-sec/2022/q3/41",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-577017.html",
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@google.com",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "There exists an unchecked length field in UBoot. The U-Boot DFU implementation does not bound the length field in USB DFU download setup packets, and it does not verify that the transfer direction corresponds to the specified command. Consequently, if a physical attacker crafts a USB DFU download setup packet with a `wLength` greater than 4096 bytes, they can write beyond the heap-allocated request buffer."
},
{
"lang": "es",
"value": "Se presenta un campo de longitud no comprobado en UBoot. La implementación de U-Boot DFU no vincula el campo de longitud en los paquetes de configuración de descarga de USB DFU, y no verifica que la dirección de transferencia sea correspondida con el comando especificado. En consecuencia, si un atacante físico diseña un paquete de configuración de descarga USB DFU con una \"wLength\" superior a 4096 bytes, puede escribir más allá del búfer de petición asignado a la pila."
}
],
"lastModified": "2026-06-17T04:41:44.320",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:denx:u-boot:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DF635F28-C38A-4034-A23B-A7EF640E6EB0",
"versionEndIncluding": "2022.07",
"versionStartIncluding": "2012.10"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve-coordination@google.com"
}