CVE-2022-22805
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 12%
- Percentil entre todas las CVEs puntuadas: 96
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (8)
CWE
- CWE-120
- CWE-120
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-22805",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "SmartConnect",
"versions": [
{
"status": "affected",
"version": "SMT Series"
},
{
"status": "affected",
"version": "SMC Series"
},
{
"status": "affected",
"version": "SMTL Series"
},
{
"status": "affected",
"version": "SCL Series"
},
{
"status": "affected",
"version": "SMX Series"
}
]
}
]
}
],
"published": "2022-03-09T20:15:08.460",
"references": [
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-120: Copia del búfer sin comprobar el tamaño de la entrada ('Desbordamiento clásico del búfer') que podría causar la ejecución remota de código cuando se reensambla un paquete TLS mal gestionado. Producto afectado: Familia SmartConnect: Serie SMT (SMT Series ID=1015: UPS 04.5 y anteriores), Serie SMC (SMC Series ID=1018: UPS 04.2 y anteriores), Serie SMTL (SMTL Series ID=1026: UPS 02.9 y anteriores), Serie SCL (SCL Series ID=1029: UPS 02. 5 y anteriores / SCL Series ID=1030: UPS 02.5 y anteriores / SCL Series ID=1036: UPS 02.5 y anteriores / SCL Series ID=1037: UPS 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS 03.1 y anteriores)"
}
],
"lastModified": "2026-06-17T04:29:04.137",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C3EA55B-DB09-4124-A9D9-A92431C38D1F",
"versionEndIncluding": "04.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "95C1E3D9-606B-4C57-A4E7-0A45C9D46332"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FFE2D844-ED18-44D3-9E75-4BB3082E4B51",
"versionEndIncluding": "04.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "154E788E-173C-4D16-A492-B61D39D420EF"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AE693F05-B0A7-452D-94C6-D36E37ACF6CB",
"versionEndIncluding": "02.9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6B138EB4-6264-4BFA-B4C7-4B23FFA676B1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C2E0803A-637E-4BBA-B9D5-AB59EE122844",
"versionEndIncluding": "02.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4175BEC7-DA4D-4E19-A642-A5FC13D3598E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
"versionEndIncluding": "02.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
"versionEndIncluding": "02.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3E52A522-88D4-4B6A-83B4-C56C093C7F54",
"versionEndIncluding": "03.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "04C627CE-E3F8-4E3F-8B93-07C92AA21296"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8",
"versionEndIncluding": "03.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9E1E7040-8123-483C-AE62-F190D83D0ADC"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}