CVE-2022-21148
Estado: ModificadaAlta (7.8)—
Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-Other
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-21148",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-21148",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-23T13:29:55.618273Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Intel(R) Edge Insights for Industrial software",
"versions": [
{
"status": "affected",
"version": "before version 2.6.1"
}
]
}
]
}
],
"published": "2022-08-18T20:15:09.870",
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00653.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Edge Insights for Industrial software before version 2.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
},
{
"lang": "es",
"value": "Un control de acceso inapropiado en el software Intel(R) Edge Insights for Industrial versiones anteriores a 2.6.1, puede permitir que un usuario autenticado habilite potencialmente una escalada de privilegios por medio del acceso local."
}
],
"lastModified": "2026-06-17T04:25:37.150",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:edge_insights_for_industrial:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8360BF31-03B3-4E72-93D0-737EC494EFCD",
"versionEndExcluding": "2.6.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}