CVE-2022-2081
Estado: ModificadaAlta (7.5)—
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.64%
- Percentil entre todas las CVEs puntuadas: 49
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- CWE-787
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-2081",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-2081",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-01-04T17:17:18.805708Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@hitachienergy.com",
"affectedData": [
{
"vendor": "Hitachi Energy",
"product": "RTU500 series CMU firmware",
"versions": [
{
"status": "affected",
"version": "12.0.1.0",
"versionType": "custom",
"lessThanOrEqual": "12.0.13.0"
},
{
"status": "affected",
"version": "12.2.1.0",
"versionType": "custom",
"lessThanOrEqual": "12.2.11.0"
},
{
"status": "affected",
"version": "12.4.1.0",
"versionType": "custom",
"lessThanOrEqual": "12.4.11.0"
},
{
"status": "affected",
"version": "12.6.1.0",
"versionType": "custom",
"lessThanOrEqual": "12.6.7.0"
},
{
"status": "affected",
"version": "12.7.1.0",
"versionType": "custom",
"lessThanOrEqual": "12.7.3.0"
},
{
"status": "affected",
"version": "13.2.1.0",
"versionType": "custom",
"lessThanOrEqual": "13.2.4.0"
},
{
"status": "affected",
"version": "13.3.1.0"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-01-04T10:15:10.927",
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000111&LanguageCode=en&DocumentPartId=&Action=Launch",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@hitachienergy.com"
},
{
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000111&LanguageCode=en&DocumentPartId=&Action=Launch",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en la función HCI Modbus TCP incluida en las versiones de producto enumeradas anteriormente. Si HCI Modbus TCP está habilitado y configurado, un atacante podría aprovechar la vulnerabilidad enviando un mensaje especialmente manipulado a la RTU500 a alta velocidad, lo que provocaría que la CMU RTU500 objetivo se reiniciara. La vulnerabilidad se debe a una falta de control de inundaciones que eventualmente, si se explota, provoca un desbordamiento de pila interna en la función HCI Modbus TCP."
}
],
"lastModified": "2026-06-17T04:41:14.917",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F5E23735-DB56-4C1E-8389-B06018CC4D9E",
"versionEndIncluding": "12.0.13",
"versionStartIncluding": "12.0.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2469A78A-6F37-4F4B-BED8-060914B2D0A4",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9E6934B-EBB2-45FB-8E4A-7D360CBA0F92",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A8966632-8645-43D6-AB52-8BC1C1BDB6DD",
"versionEndIncluding": "12.6.7",
"versionStartIncluding": "12.6.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F12F1A20-9D3C-4F2B-B538-8B4EABD288C9",
"versionEndIncluding": "12.7.3",
"versionStartIncluding": "12.7.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F7A0F9D4-E9ED-4351-8909-EEE689DE2BF4",
"versionEndIncluding": "13.2.4",
"versionStartIncluding": "13.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:13.3.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1621CAF4-C18A-48B5-82AC-F8D09105656A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "11AF93AD-200F-47A6-BA2C-F82165AFB50D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BB001482-F203-4731-A6DD-6BCE3C1338CA",
"versionEndIncluding": "12.0.13",
"versionStartIncluding": "12.0.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "79BC5D4A-09B2-41FB-962A-CF580181EB2C",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A30CDB2F-E0CC-4440-9E59-AB339F94996F",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "56598D9D-5BCB-42C6-8705-AB79C4BD2A9A",
"versionEndIncluding": "12.6.7",
"versionStartIncluding": "12.6.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B4FDE92C-733F-4B52-8BE6-E37898B39075",
"versionEndIncluding": "12.7.3",
"versionStartIncluding": "12.7.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2209D1D9-94CD-4D8B-BB80-39CC129FEEF4",
"versionEndIncluding": "13.2.4",
"versionStartIncluding": "13.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:13.3.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BACEC63E-0548-483F-813E-C04F4C95970E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FC6F9377-E6BB-4DEA-9D87-0AF792CBAC57"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8F1F7579-050B-4216-A4D5-FD74C8A19618",
"versionEndIncluding": "12.0.13",
"versionStartIncluding": "12.0.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "803838B5-058E-436B-8CE5-BF711456F96B",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A0361A98-1496-4763-A489-DCAE0D0DF613",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "762AB8CE-068D-46D4-A275-154A2AC58E55",
"versionEndIncluding": "12.6.7",
"versionStartIncluding": "12.6.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4DF9263A-D1DB-4899-99C2-88B59847C808",
"versionEndIncluding": "12.7.3",
"versionStartIncluding": "12.7.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "15B3C46C-0A5E-4142-A096-94A513DD8004",
"versionEndIncluding": "13.2.4",
"versionStartIncluding": "13.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:13.3.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E8B2A709-9538-47C9-9E70-DBC1D2817E79"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6EEFDEF0-883D-402B-9CD4-333A145E3C75"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0708BD2D-FEA4-4C97-9C3A-B4E67EA3D926",
"versionEndIncluding": "12.0.13",
"versionStartIncluding": "12.0.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6BDB5A36-9B2F-43F9-A81B-506C4660151F",
"versionEndIncluding": "12.2.11",
"versionStartIncluding": "12.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F25FBFD5-BC45-49C9-87D4-A9C05405490D",
"versionEndIncluding": "12.4.11",
"versionStartIncluding": "12.4.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0505DF4D-0B06-4E61-B756-C2B5D31B85A0",
"versionEndIncluding": "12.6.7",
"versionStartIncluding": "12.6.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9495E9A9-733C-4073-8B39-1A08A88B05A7",
"versionEndIncluding": "12.7.3",
"versionStartIncluding": "12.7.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "269F1D56-A575-487D-B5ED-4E774C26BA3B",
"versionEndIncluding": "13.2.4",
"versionStartIncluding": "13.2.1"
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:13.3.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "530437F6-6F90-45D5-821C-B87C292C0CCC"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "495DCBD6-D2D1-4295-81D1-6ACA1B2CA223"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@hitachienergy.com"
}